Skip to Content

For IT teams

AEC Pilot for IT Administrators

What an IT team needs to allow AEC Pilot on company computers: the addresses it connects to, the ports it opens on the computer itself, how it installs, and what data leaves the computer.

Website blocked by a company web filter?

aecpilot.com is a new domain: HMK Tools moved here from hmktools.com in September 2026 and became AEC Pilot. Some web filters block new domains for their first weeks, or until they have put the site in a category. Allowing the addresses below solves it at once.

Addresses to Allow

All connections go out from the computer over HTTPS, port 443. Nothing connects in from outside, so no inbound firewall rule is needed.

AddressUsed for
www.aecpilot.comThe website: download, account and licences, documentation. Opened in the browser.
licensing.aecpilot.comLicence check and activation from inside the Autodesk applications: when an application starts, then at most once an hour.
aec-licensing.aecpilot.workers.devBackup address of the same licence server, used only when the first one does not answer.

Only needed for the features that use them:

AddressUsed for
api.anthropic.com
api.openai.com
generativelanguage.googleapis.com
api.deepseek.com
Pilot AI chat inside the application, with the provider the user picks: Claude, OpenAI, Google Gemini or DeepSeek. The user’s own API key is used, and the conversation goes directly from the computer to that provider, not through AEC Pilot.
developer.api.autodesk.comRevit only: browsing cloud models in Autodesk Docs, with the user’s own Autodesk sign-in.

AEC Pilot uses the computer’s proxy settings. If your proxy inspects HTTPS traffic, Windows must trust its root certificate.

AEC Pilot never downloads or installs updates by itself. When a new version is out it shows a notice, and installing it stays with the user or IT.

AEC Pilot on a company network: outbound HTTPS 443 to the licence server, the website and, if used, the AI provider; local servers answer 127.0.0.1 only; nothing inbound

Ports on the Computer Itself

So that AI assistants such as Claude Desktop, Cursor or Codex can work with the open model, each Autodesk application opens a small local server. It answers only requests from the same computer (127.0.0.1) and refuses every other address. It takes the first free port in its range:

ApplicationPorts
Revit7823–7838
AutoCAD, Civil 3D, Advance Steel7900–7915
Navisworks7950–7965
Inventor8000–8015
3ds Max8050–8065
Robot Structural Analysis8100–8115

These ports need no firewall rule.

Installation

  • One installer adds AEC Pilot to every supported Autodesk application it finds: AECPilot_v…_Setup.exe, on the download page.
  • It installs for all users of the computer and needs administrator rights.
  • Program files go to C:\Program Files\7Dimensions\AEC Pilot\. The add-ins are registered in each Autodesk application’s standard add-in folder.
  • In Installed apps it appears as AEC Pilot™ All-in-One, publisher 7Dimensions OÜ.
  • Setup asks for the Autodesk applications to be closed before it installs or updates.

Allow the publisher, not the certificate

The installer and the add-ins are signed with a Microsoft-issued code-signing certificate in the name of 7Dimensions OÜ. The certificate is renewed every few days, so allow-list the publisher name, not a certificate thumbprint.

Silent install: run the installer with /VERYSILENT /SUPPRESSMSGBOXES, and add /LOG="C:\Temp\aecpilot-setup.log" for a log. If an Autodesk application is still open, setup stops without installing, and the log says why.

Rolling it out to many computers with a software-distribution tool? Write to support@aecpilot.com and we will help.

Automatic Updates

  • The installer from the download page also adds a scheduled task, \7Dimensions\AEC Pilot Updater. It runs as SYSTEM at start-up and every 4 hours, so updates need no administrator after the first install.
  • It reads https://www.aecpilot.com/aec-pilot-update.json. A newer version is downloaded from www.aecpilot.com and installed only if it is signed by 7Dimensions OÜ and its SHA-256 checksum matches.
  • It installs only while no Autodesk application is open, never installs an older version, and keeps AEC Pilot in the same Autodesk applications.
  • Log: C:\Program Files\7Dimensions\AEC Pilot\Updater\logs\updater.log. AEC Pilot from the Autodesk App Store does not update itself.

To switch it off, set the DWORD value DisableAutoUpdate = 1 under HKLM\SOFTWARE\Policies\7Dimensions\AEC Pilot (Group Policy or Intune), or install with /NOAUTOUPDATE. Users are then told in their Autodesk application when an update is available. The updater uses the computer's proxy settings; a proxy that asks for a user sign-in blocks it.

What Data Leaves the Computer

  • Licence check: the licence key, the Windows machine ID and computer name, the AEC Pilot version, and which Autodesk application and version is running. The username is sent once, at activation.
  • Usage statistics: on by default; each user can switch them off in Pilot Chat Settings. They count which tools are used, how often they fail and how long they take, with the Windows and Autodesk versions and languages. They never contain models, drawings, file or project names, prompts or AI replies. To switch them off for everyone on a computer, set the DWORD DisableUsageStatistics = 1 under HKLM\SOFTWARE\Policies\7Dimensions\AEC Pilot (Group Policy or Intune); under HKCU it applies to one user. Counting then stops within a minute, what was counted on the computer is deleted, and the switch in Pilot Chat Settings is greyed out.
  • Code samples: on by default; each user can switch them off in Pilot Chat Settings. They hold the code the AI runs in AEC Pilot's code tools and whether it worked, with user names, the computer name and e-mail addresses removed. To limit them to the outline of the code (no text, numbers or file names) for everyone on a computer, set the DWORD DisableCodeSamples = 1 under HKLM\SOFTWARE\Policies\7Dimensions\AEC Pilot; DisableUsageStatistics = 1 stops them completely.
  • Pilot AI: goes directly to the AI provider the user chose, with the user’s own key. AEC Pilot servers never see these conversations.

Models, drawings and project files are never sent to AEC Pilot. More in the privacy policy.

Files on the Computer

  • %APPDATA%\7Dimensions\AECPilot\: the licence and tool settings. The licence is encrypted for the Windows user.
  • %LOCALAPPDATA%\7Dimensions\AECPilot\: Pilot AI settings, conversations and logs. AI provider keys are stored encrypted for the Windows user.

Read-only Mode

AEC Pilot can be limited to reading. The AI assistant can still look at models and drawings, list, count and report, but every tool that can change them is switched off: creating, deleting, changing parameters or properties, saving and running custom code. Such a tool is not offered to the assistant, and it is refused if it is called. Read-only mode is off by default.

A user can turn it on in AEC Pilot under Settings > Security. To set it for everyone on a computer, set the DWORD value ReadOnly = 1 under HKLM\SOFTWARE\Policies\7Dimensions\AEC Pilot (Group Policy or Intune); the same value under HKCU sets it for one user.

While the policy is set, the Settings checkbox shows as on and cannot be turned off. AEC Pilot reads the value within 30 seconds, so no restart is needed; an assistant that is already connected should reconnect to get the shorter tool list. To lift the policy, delete the value or set it to 0.

Pilot Chat: Files and PowerShell

Pilot Chat, the assistant inside the Autodesk applications, can read the files and folders a user points it to and, after the user approves each change, create, copy, move or delete files. Replaced and deleted files go to the Recycle Bin; on a network drive the old file is kept next to it as a .bak copy. System folders (Windows, Program Files), browser and credential folders and AEC Pilot's own settings are never read. Files that can run (.exe, .bat, .ps1, add-in manifests and similar) are never written, and nothing is written to start-up or add-in folders. File access is on by default.

As a last resort Pilot Chat can also run a PowerShell command, as the signed-in user and never as administrator. This is off by default. A user can turn it on in Pilot Chat Settings; every command is then shown in full and must be approved each time. Commands that format disks, change security settings, create scheduled tasks or services, download and run code, or close the Autodesk application are refused without asking. The commands that ran are kept for 30 days in %LOCALAPPDATA%\7Dimensions\AECPilot\Pilot\powershell\.

To switch these off for everyone on a computer, set DWORD values under HKLM\SOFTWARE\Policies\7Dimensions\AEC Pilot (Group Policy or Intune); the same values under HKCU apply to one user:

  • DisablePilotChatFiles = 1: no file access at all, neither reading nor changes.
  • DisablePilotChatFileWrites = 1: files can be read but not created, changed or deleted. This also stops Pilot Chat from saving tables as Excel or CSV files.
  • DisablePilotChatPowerShell = 1: no PowerShell commands.

While a value is set, the matching switch in Pilot Chat Settings is greyed out and cannot be turned on. Pilot Chat reads the values within 30 seconds, so no restart is needed. To lift a policy, delete the value or set it to 0. These values apply to Pilot Chat.

Requirements

  • Windows 10 or 11, 64-bit.
  • At least one supported Autodesk application; see Getting started.
  • Nothing else to install: the add-ins run on the Autodesk application’s own .NET runtime.

Questions from your IT team: support@aecpilot.com.